Re: ICD2 一直出現ICD0031/0275 是不是壞了!
#3
資深會員
資深會員


查看用戶資訊
也許是 16F690 相關的 files 壞了 只要是用 icd2 + 16f690 就掛了.

我用 app013 18f4550 , app001 18f4520 又都正常

可能會要把 mplab 8.3 重灌

發表於: 2009/7/5 11:11
Twitter Facebook Google Plus Linkedin Del.icio.us Digg Reddit Mr. Wong 頂部


Re: ICD2 一直出現ICD0031/0275 是不是壞了!
#2
版主
版主


查看用戶資訊
建議一下,以後看到 ICD 的錯誤時,只要在 ICD0031 的字上直接點選兩次後就會自動帶出此錯誤的相關訊息,先看一下錯誤發生的原因。底下就是 ICD0031 的錯誤提示: 建議先以手動方式換一下 ICD2 的 F/W。

General API Error Actions
MPLAB IDE and MPLAB ICD 2 are out of sync with each other. Here are some common reasons and corrective actions.

1. Reconnect to the MPLAB ICD 2.
2. Try the operation again. It is possible the error was a one time glitch.
3. The version of MPLAB IDE installed may be incorrect for the version of firmware loaded on the MPLAB ICD 2. Follow the steps outlined in <General Corrupted Installation Actions>, and then manually download the MPLAB ICD 2 Operating System.
4. If the problem persists contact Microchip.

發表於: 2009/6/30 9:43
Twitter Facebook Google Plus Linkedin Del.icio.us Digg Reddit Mr. Wong 頂部


ICD2 一直出現ICD0031/0275 是不是壞了!
#1
資深會員
資深會員


查看用戶資訊
開起 mplab IDE 及 project file 都ok

燒錄 16F690 ICD2 一直出現ICD0031/ ICD0275 message
正常690程式只耗 1.9mA, 不正常的都 18.9mA, 都會正常工作.

全新的690 也一樣, Icd2 error 會亮, 然後死當, 必須離開 MPLAB IDE .

==================================

Connecting to MPLAB ICD 2
...Connected
Setting Vdd source to target
Target Device PIC16F690 found, revision = Rev 0x6
...Reading ICD Product ID
Running ICD Self Test
...Passed
MPLAB ICD 2 ready for next operation
Programming Target...
...Validating configuration fields
...Erasing Part
...Programming Program Memory (0x0 - 0xFFF)
Verifying...
...Program Memory
ICD0031: API: Framing error
ICD0275: Programming failed.
MPLAB ICD 2 ready for next operation

發表於: 2009/6/26 17:46
Twitter Facebook Google Plus Linkedin Del.icio.us Digg Reddit Mr. Wong 頂部







You can view topic.
不可以 發起新主題
You cannot reply to posts.
You cannot edit your posts.
You cannot delete your posts.
You cannot add new polls.
You cannot vote in polls.
You cannot attach files to posts.
You cannot post without approval.
You cannot use topic type.
You cannot use HTML syntax.
You cannot use signature.
You cannot create PDF files.
You cannot get print page.

[進階搜尋]


:::

Microchip連結

https://www.facebook.com/microchiptechnologytaiwan/
http://www.microchip.com.tw/modules/tad_uploader/index.php?of_cat_sn=13
https://mu.microchip.com/page/tmu
http://elearning.microchip.com.tw/modules/tad_link/index.php?cate_sn=1
https://page.microchip.com/APAC-PrefCenters-TW.html
http://www.microchip.com/
http://www.microchip.com/treelink
http://www.microchipdirect.com/
http://www.microchip.com.cn/newcommunity/index.php?m=Video&a=index&id=103
http://www.microchip.com.tw/modules/tad_uploader/index.php?of_cat_sn=2
http://www.microchip.com.tw/Data_CD/eLearning/index.html
http://www.microchip.com.tw/RTC/RTC_DVD/
https://www.microchip.com/development-tools/
https://www.youtube.com/user/MicrochipTechnology
[ more... ]

教育訓練中心

!開發工具購買
辦法說明 [業界客戶] [教育單位]
----------------------------------
!校園樣品申請
辦法說明 [教師資格] [學生資格]
----------------------------------